Raysemble: Metric 3D Spine and Pelvis From One X-ray

Fig. 4a of arXiv:2611.16869 by Li, Yan and Chai: a simulated AP radiograph of the lumbar spine and pelvis, 3D bone reconstructions from VolumeNeRF and Raysemble next to the CT reference, and sagittal CT slices with predicted and CT bone outlines.

An AP radiograph of the lumbar spine and pelvis is one of the cheapest images in orthopedics, and it is flat. Surgeons who want a 3D view of the vertebrae or the hip bones usually order a CT, with the dose and cost that come with it. Xiaoyang Li, Xinghao Yan and Yuan Chai at the ORBIT Lab of Northeastern University in Shenyang, with Chai also at the Australian National University (arXiv:2611.16869, first posted 12 November 2026, v3 on 20 November), present Raysemble, a model that rebuilds eight bones in 3D from that one AP image: L1 to L5, the sacrum and both hip bones. It also places them at their physical size and position in millimeters.

Raysemble predicts what each bone looks like and where it sits as two separate problems, then uses the X-ray camera geometry to put them back together.

Why one X-ray is hard to lift into 3D

The paper names three ambiguities. A single projection hides depth, so two bones at different distances from the detector can cast nearly the same outline. Cone-beam magnification couples depth and apparent size, so a bone closer to the source looks bigger than it is, and the network cannot tell a large bone from a nearby one by its shadow alone. And in an AP view of the lower spine and pelvis, the sacrum, the hips and the lower lumbar vertebrae overlap. Methods that synthesize a whole CT volume from the X-ray and then segment it have to resolve all three at once, inside one big generator.

How the pipeline works

Bone maps first. Raysemble does not start from raw pixels. A frozen copy of FleXray, a public universal X-ray segmenter from MIT, turns the AP image into soft probability maps for L1 to L5, the sacrum and a combined hip class, which is split into left and right at the predicted sacral centroid. Each bone gets a square region of interest drawn around its largest confident blob.

An initial guess at placement. From those maps, a small head predicts an image center, a size and a depth for each bone, starting from an average depth learned from the training set and allowed to move by a bounded number of millimeters. Back-projecting along the X-ray ray gives a first 3D center and box size.

Shape on a normalized grid. Inside each bone’s box, the model lays out a 12 x 12 x 12 grid of 3D query points. Every query is projected once into the X-ray using the known source and detector distances, and at that one detector position it samples two feature maps: a full-image map that carries surrounding anatomy and a cropped map that carries local bone detail. Those features nudge a mean latent code for that bone, and a shared decoder, pretrained as an autoencoder on CT bone masks, upsamples it to a 96 x 96 x 96 occupancy volume in a normalized cube. At this stage the bone has a shape but no physical size.

Final placement with a magnification fix. A separate branch takes the probability maps and the image and predicts a shared depth shift for the whole skeleton plus a per-bone adjustment. When a bone moves farther from the source, the method scales it up by the ratio of source distances, because a fixed outline at greater depth implies a physically larger bone. This step is plain projection geometry, with only a small learned residual on top.

Assembly. Each local occupancy is placed with its final center and scale, resampled onto a common 128 x 128 x 160 grid spanning roughly 48 x 29 x 57 cm, and every voxel takes the most likely bone label above 0.5. The output is an eight-label 3D mask in a right, anterior, superior frame. The reconstruction network itself has 0.79 million parameters; with the frozen FleXray front end, the whole system has 102.19 million, about half of the adapted VolumeNeRF baseline.

The featured image above shows one test case from Fig. 4a of the paper: the simulated AP input, the 3D bones from VolumeNeRF given the same inputs, Raysemble’s bones, and the CT reference, with sagittal CT slices underneath where the white outline is CT and the orange outline is the prediction.

What the results show

Training and testing used 419 CT scans from 225 subjects in the CT-TRI and AbdomenCT-1K subsets of the CADS collection. Each scan was rendered into one digitally reconstructed AP radiograph with DiffDRR, using a fixed cone-beam geometry (1050 mm source to isocenter, 1200 mm source to detector). Reference bone masks came from TotalSegmentator. The test set holds 43 scans from 23 patients, kept fully separate from training subjects.

The authors compared 15 configurations on the same eight-bone task: a plain 2D-to-3D U-Net baseline, adaptations of published methods ranging from CT synthesis models such as XctDiff and VolumeNeRF to bone-focused ones such as 3DDX and a joint 2D to 3D statistical shape model, and Raysemble. Scored directly in millimeters before any alignment to CT, Raysemble came first on all three metrics, with a mean Dice of 65.24% and an average surface distance of 3.32 mm. In a matched comparison, VolumeNeRF received the same image, the same FleXray maps, the same bone regions and the same camera parameters, and its synthesized CT was segmented afterwards. Raysemble improved Dice by 5.86 points on average and lowered both surface distance metrics for all 23 test patients. The segmenter used on VolumeNeRF’s output reaches 91.82% Dice on real CT but 59.38% on the synthesized volumes, which suggests much of the loss on that route happens in the CT synthesis step.

Two real pelvic radiographs from the First People’s Hospital of Dali City, with X-ray and CT acquired 16 and 70 days apart, were run with nominal camera settings and rigidly aligned to an automatically segmented CT pelvis. Raysemble scored higher than matched VolumeNeRF on all three metrics in both cases. The authors call this exploratory, and the 16-day case was used during development.

Where it falls short

  • Simulated radiographs. Every quantitative number comes from DRRs rendered from CT with one fixed camera geometry and no patient rotation. Real AP films vary in source distance, tube angle, positioning and exposure.
  • Two real cases. The clinical check is two patients from one hospital, one of them seen during development, scored only after rigid alignment.
  • Camera calibration is required. The placement branch relies on known source and detector distances. The authors note that magnification errors can be mistaken for bone-size errors, so metric output needs calibrated geometry.
  • No per-bone rotation. Placement predicts a center and a scale for each bone. Orientation comes from the normalized shape, so a strongly rotated vertebra, as in scoliosis, would depend on the shape branch alone.
  • Coarse output grid. The assembled volume has voxels of roughly 3.8 x 2.3 x 3.6 mm. That is enough for bone position and gross shape, not for fine surface detail or small fractures.
  • Automatic references and screened data. Ground truth is TotalSegmentator masks, scans were screened for metal and field of view, and truncated bones can throw off the region of interest. The paper says clinical measurements need independently annotated references.
  • The placement gain is small. With shape held fixed, the absolute depth branch improves mean Dice only slightly, and the paired confidence interval includes zero.

Where it fits for an imaging platform

For an orthopedic viewer or a planning tool, Raysemble outputs labeled bone meshes in millimeters next to the original radiograph, and each step can be inspected: the FleXray maps, the per-bone boxes, the normalized shapes and the final placement. A viewer could show the 3D bones beside the AP film for patient education, rough implant sizing or follow-up when no CT exists, as long as the source and detector distances are stored with the image. DICOM X-ray objects often carry them in the Distance Source to Detector and Distance Source to Patient attributes, so the calibration data frequently already sit in the header.

Raysemble is still a research result on simulated images. Before any measurement leaves the screen, it would need real paired X-ray and CT data, varied positioning and annotated references.

Code, weights and licence

The paper does not link any code, and when we searched GitHub and Hugging Face on 23 November 2026 we found no Raysemble repository or weights. The front end it depends on is public: VictorButoi/FleXray is MIT licensed, but its pretrained weights on Hugging Face are released under CC BY-NC 4.0, which rules out commercial use without separate permission. The training CT data come from public collections, and the paper is distributed under arXiv’s standard non-exclusive licence.

Source

Xiaoyang Li, Xinghao Yan and Yuan Chai, “Raysemble: Metric 3D Bone Reconstruction from a Single X-ray”, arXiv:2611.16869 (v1 12 November 2026, v3 20 November 2026), preprint. Affiliations: ORBIT Lab, College of Medicine and Biomedical Information Engineering, Northeastern University, Shenyang, China; The John Curtin School of Medical Research, Australian National University, Canberra (Y. Chai). Featured image: panels from Fig. 4a of the paper (simulated AP input, matched VolumeNeRF, Raysemble, CT reference and sagittal CT overlays for test case A), cropped from the PDF, resized, with labels added.