Thoracic Planning CT In, OAR Target Overlays and Uncertainty-Guided RTSTRUCT Out

Hang a thoracic planning CT into DAMM-Net++: multi-structure OAR and target overlays, calibrated uncertainty for triage, and TPS-ready RTSTRUCT. Macro Dice 0.955 / HD95 ~3.78 mm; reader study ~75-80% less contouring time. arXiv:2609.16036.
Whole Fetal Ultrasound Study In, CHD Screen and Top Supporting Frames Out

Hang a whole fetal ultrasound study into cardiac-gated MIL (FUSE CHD screen): case-level CHD vs healthy, optional critical vs non-critical severity, plus top attention-ranked frames for review. Internal AUC 0.985 / specificity 0.990; CARDIUM 0.513 to 0.944 with CORAL. arXiv:2609.31376.
Motion-Corrupted DWI Stacks In, Slice-to-Volume Alignment Out That Beats Eddy on Jerky Sparse Scans

Hang motion-corrupted DWI stacks into GraphSVR: stack-wise rigid slice-to-volume transforms that cut grid/rotation error ~73% vs FSL eddy under severe motion, strongest on sparse 12/24/32-direction jerky cases. arXiv:2609.24732.
Weak Ultrasound Lesion Overlay In, Progressively Repaired Contour Out Without Retraining the Base Model

Hang a weak ultrasound lesion overlay from a frozen segmentor, then progressively repair gross miss, FN gaps, and FP blobs with FAPR without retraining the base model. Hard-case BUSI/TN3K average +13.77%. arXiv:2609.18256.
Liver CT In, Organ Tumor Vessel Overlays Physical Volumes and Resection Plan Out

Hang a liver CT and get organ/tumor/vessel overlays, physical volumes and distances from Port B, plus a simulator-shielded resection sequence from VoxelSage. Dual-port: language orchestrates, image math stays off the LLM. arXiv:2609.37648.
Few Clicks on a 3D CT or MR Volume In, Complex Anatomy and Pathology Overlays Out

Hang a few points or a 2D box on a 3D CT/MR volume and get full-volume anatomy and pathology overlays from SAMI3D-DW. Category-macro Dice 0.8002 after box plus five clicks on 107 categories / 4326 cases. arXiv:2609.25743.
Speckled Ultrasound In, Anatomy-Keeping Despeckled Frames Out Without Clean Targets

Hang a speckled ultrasound frame and get a despeckled view that keeps fine anatomy from Mask2Restore. Block-wise masked inpainting plus CRCR, no clean target at train time. Simulated SSIM 0.810, PSNR 20.36. arXiv:2609.32844.
Fetal Brain Label Map In, Realistic 3D Ultrasound Volume Out Without Paired MRI-US Training at Inference

Hang an anatomical fetal brain label map and get a realistic 3D ultrasound volume from AWR-Net. ACWD wavelet diffusion then AARL residual refinement. US-Real test SSIM 0.470, PSNR 15.648, NCC 0.518, FetalCLIP FID 8.905. arXiv:2609.22635.
Clinical Phrase Plus Chest Scan In, Infection Overlay Out Without a Full Retrain

Hang a clinical phrase with a chest X-ray or CT slice and get a text-conditioned infection overlay from MRSeg. Frozen ConvNeXt and PubMedBERT, routed Pair Adapter, Region Bridge. 90.90 Dice on QaTa-COV19, 81.53 on MosMedData+, 7.11M trainable params. arXiv:2609.28860.
Broken Vessel Mask In, Connected Overlay Out for Centerlines and Graphs

Hang a broken nnU-Net vessel mask and get a mesh-guided reconnection for centerlines and graphs. ccDice jumps aorta 0.596→0.992, TopCoW 0.722→0.835, PARSE 0.028→0.862 while Dice stays flat. arXiv:2609.29779.