Deep-learning denoisers for low-dose CT often score a high PSNR and still produce images that look too smooth. The grain readers are used to is gone and the soft tissue looks waxy. If you ship a viewer or a reconstruction add-on, that is the complaint you are likely to hear from radiologists.
A group at the Biomedical Imaging and AI Laboratory of Istanbul Technical University proposes a fix in arXiv:2611.25548 (posted 19 November 2026, submitted to IEEE ISBI 2027). They call it LBW-NPS, a local band-weighted noise power spectrum loss. It is a training loss, not a new network: you keep your denoiser, add one term, and the output keeps more of the reference image’s texture.
The idea in plain terms
The noise power spectrum (NPS) describes how much energy an image has at each spatial frequency, which is a standard way to describe CT noise texture. Earlier work already used NPS-style terms as a training loss. The usual version compares one pooled spectrum for the whole image or crop. The authors point out that a deficit of high-frequency power in one region can be cancelled by an excess somewhere else, so the pooled spectrum can look right while parts of the image have the wrong texture.
LBW-NPS avoids the cancellation by comparing locally. The image is cut into overlapping 64 by 64 pixel windows with a stride of 32, each window gets a Hann taper, and its power is summed into three radial frequency bands: 0 to 0.15, 0.15 to 0.35 and 0.35 to 0.5 cycles per pixel. For every window and band the loss takes the log ratio between the denoised and the normal-dose image, squares it, and averages over windows. The band weights are 0.5, 1 and 2, so the high-frequency band counts most. Squaring before averaging is what stops opposite errors from cancelling.
Only windows where at least 90% of the reference pixels fall inside the body mask are used, and the mask comes from TotalSegmentator, but the tissue type never enters the loss. And because the spectrum ignores phase, the loss is always paired with a plain L1 pixel term that keeps the anatomy in the right place.
How it was tested
The authors took 1,301 slices of 512 by 512 pixels from 180 patients in the public DeepLesion dataset as normal-dose references. For each slice they simulated a low-dose scan: forward projection in parallel-beam geometry, Poisson noise at 105 incident photons, and filtered back projection. The split is by patient, 899 slices for training, 182 for validation and 220 for testing (115, 34 and 31 patients).
Every loss used the same 7.76-million-parameter residual U-Net, trained for 40 epochs with three random seeds. LBW-NPS was compared with L1 alone and five add-ons: pooled NPS with uniform bands, pooled NPS with weighted bands, Focal Frequency Loss, a VGG feature loss without adversarial training, and a Pearson divergence loss. The loss weight for LBW-NPS was 0.0007. Their validation rule would have picked 0.002, which cost 0.55 dB of validation PSNR, so they chose the smaller value to protect pixel fidelity and do not claim it is optimal.
What came out
The headline number is a local spectral gap measured on 64 by 64 windows with uniform band weights. Against the pooled band-weighted NPS loss, LBW-NPS lowers it from 0.559 to 0.380, a 31.9% reduction, and L1 alone sits at 0.848. PSNR stays at 44.17 dB, against 44.35 dB for L1 alone and 44.38 dB for Focal Frequency Loss, and the difference to the pooled loss is not significant. So the texture improves and the pixel metric barely moves. LPIPS drops from 0.0585 (L1 alone) to 0.0418, second best after the VGG loss at 0.0390.
Because the local gap is built from the same spectral machinery as the loss, the authors also checked measures the loss never sees, in up to eight homogeneous 32 by 32 soft-tissue windows per slice (197 slices from 30 patients). The error in average spectral frequency falls from 0.0448 to 0.0317 cycles per pixel against the pooled loss, and the error in GLCM contrast (a classical texture statistic) falls from 0.696 to 0.412.
The ratio of high-band power between output and reference ends at 0.84 for LBW-NPS, closest to the ideal of 1, while L1 alone and Focal Frequency Loss are at 0.31. L1 training discards most of the high-frequency power, which matches the smooth look described above.
What the featured image shows
The featured image reproduces the abdomen and thorax crops of Fig. 2 in the paper: the simulated low-dose input, the L1-only output, the LBW-NPS output and the normal-dose reference. Two further columns of the original figure (pooled NPS and Focal Frequency Loss) are left out to keep the picture readable. The crops are 96 pixels wide and shown at a window of -175 to 275 HU. In the abdomen the L1 result looks smoother than the reference, and the LBW-NPS result keeps a grainier surface. In the thorax the differences between denoisers are small, and the authors say so themselves.
Why a viewer or reconstruction team would care
If your product offers an AI denoising or dose-reduction step, texture is often what decides whether radiologists accept it. The loss adds no layers and no inference cost, since it only exists at training time. The weight, the bands and the window size are three knobs you can tune on your own data. The paper’s local band-power gap against the reference is also easy to compute on your own outputs and says more about texture than one global PSNR when you compare candidate models.
For a viewer, the practical consequence is to keep the original series one click away from the denoised one, since a model that scores well on a pixel metric can still look different from what readers know.
Limits to keep in mind
- The study uses one simulated dose level, one dataset and one backbone. Real scanner noise, other reconstruction kernels and other architectures are not tested.
- The spectrum is of the image, so it also contains anatomy. The authors call it an image-texture surrogate, not a pure noise estimate, and the local gap metric shares its construction with the loss.
- The pooled and local losses differ in more than the pooling order (region selection and spectral averaging as well), so the paper does not isolate pooling as the only cause.
- In lung, tissue-conditioned pooling did better (0.498 against 0.593 for LBW-NPS). Soft tissue favoured LBW-NPS (0.498 against 0.624), and bone showed no significant difference. Lung and bone cover only 15 patients each.
- PSNR and LPIPS do not make LBW-NPS the best on every measure, and the authors state that better texture statistics do not establish lesion visibility or diagnostic benefit without a task-based or reader study.
Licence, code and status
The paper is an arXiv preprint (eess.IV, 5 pages) under the standard arXiv licence, and it is submitted to IEEE ISBI 2027, so it has not been peer reviewed yet. The code is public at github.com/itu-biai/lbw-nps with training and evaluation scripts, configs for the seven main losses and the patch-size variants, and aggregate result tables. The README states a CC BY-NC 4.0 licence, so commercial use needs permission from the authors. CT images, patient identifiers, trained weights and logs are not included, and you have to rebuild the simulated low-dose arrays from DeepLesion yourself.
Source: Yalçındağ, Ünal, Ertaş and Yıldırım, “LBW-NPS: A Local Band-Weighted Noise Power Spectrum Loss for Texture-Preserving Low-Dose CT Denoising”, arXiv:2611.25548. Figure reproduced from the preprint with credit to the authors.