Skip to content
  • Home
  • Services
    • All Services
    • Custom DICOM Viewer
    • Case Studies
  • Products
    • All Products
    • PYCAD DICOM Viewer
    • PYCAD Dental Viewer
    • PYCAD SSR Engine
  • Case Studies
  • Blog
  • About us
  • Home
  • Services
    • All Services
    • Custom DICOM Viewer
    • Case Studies
  • Products
    • All Products
    • PYCAD DICOM Viewer
    • PYCAD Dental Viewer
    • PYCAD SSR Engine
  • Case Studies
  • Blog
  • About us
Get in Touch

Category: DICOM & Viewers

MedImgAnnotator: Batch Annotation for Large CT and MRI Cohorts

Fig. 1 of arXiv:2611.22450 by Kassaw et al.: the MedImgAnnotator main window showing an abdominal diffusion MR slice with multi-organ labels overlaid, a mask-only preview and a per-label volume and annotation time panel.

A Windows tool that queues folders of CT and MRI, pairs each scan with its predicted mask, and cuts the time spent per case.

SWIMSS: An Open MS Lesion Segmenter Trained on Seven Swiss Centres

Figs. 1 and 2 of arXiv:2611.23351 by Spagnolo et al.: two axial FLAIR brain MRI test cases with multiple sclerosis, showing the input, the expert-corrected ground-truth lesion mask, the LST-AI mask and the SWIMSS24 mask in red.

A SwinUNETR trained on 1,385 people with MS from seven Swiss centres segments white matter lesions from FLAIR and MPRAGE, even on a CPU.

GRACE: Fixing Segmentation Masks With Retrieved Verified Cases

Fig. 5 of arXiv:2611.23189 by Marcianò et al.: liver, pancreas and spleen CT and prostate peripheral zone MRI slices showing the ground-truth mask, a synthetically damaged mask and its GRACE correction, and a MedSAM2 mask and its GRACE correction.

One refiner, trained once on CT, MRI and ultrasound, corrects a model’s mask using a verified case of the same organ from a library.

PathoDraw: One Zero-Shot Lesion Detector for Any Brain MRI

Fig. 3 of arXiv:2611.21975 by Roberts et al.: axial brain MRI from ATLAS T1w, BraTS FLAIR and T2w, WMH FLAIR and a clinical PRES FLAIR scan, with the input image, ground-truth outline in green with the PathoDraw lesion mask in pink, and the signed deviation map in blue and red.

Trained only on synthetic lesions, one network flags stroke, glioma and white matter lesions on T1w, T2w or FLAIR brain MRI.

Plug-and-Play Prior vs Tuned TV: Sparse-View CT Beyond PSNR

Fig. 20 of arXiv:2611.18936 by Mohammed Abo Oraig: crops of three LoDoPaB-CT slices reconstructed from 60 views at full dose with Hann-filtered FBP, total variation, a Plug-and-Play DnCNN prior and PnP started from TV, red circles marking the strongest lesion-like blob not supported by the reference image.

A DnCNN prior roughly matches a well-tuned TV on real sparse-view CT, but PSNR and lesion detection rank the methods differently.

Scribble Once: Echo Cine Segmentation From One Scribbled Frame

Fig. 2 of arXiv:2611.21137 by Vincent Li Weixin, Chen Jingkun and Vicente Grau (University of Oxford, Northwestern Polytechnical University): CAMUS two-chamber echo frames with left-ventricle endocardium masks from U-Net, CutMix, CycleMix, ScribFormer, HELPNet and the single-scribble method, per-frame Dice printed in each panel.

Two scribbles on one frame per clip train a LoRA-adapted DINOv3 model to segment heart chambers across the whole echo sequence.

SIM: Zero-Shot MRI Reconstruction Learned From Simulated Data

Fig. 7a of arXiv:2611.15758 by Shang, Zhan, Jia and co-authors (SIAT Chinese Academy of Sciences, Peking University Shenzhen Hospital, Tencent): T1, T2 and FLAIR brain MRI from an Alzheimer's disease cohort, fully sampled reference above zero-shot SIM and E2EVarNet reconstructions at three accelerations, red arrows on residual aliasing.

A one-billion-parameter transformer trained on simulated k-space from photos reconstructs MRI from scanners it never saw, 0.3 T to 7 T.

X-Strata: Separating Aneurysm and Vessel Layers in 2D Angiography

Supplementary Fig. S3 of arXiv:2611.17743 by Wen, Chen, Li and co-authors (Tsinghua University, Hunan University, Chinese PLA General Hospital): six pairs of peak cine DSA frames of intracranial aneurysms next to layer overlays with the sac in blue, vessels in front in gold, vessels behind in gray and overlap in pink.

From two routine DSA cine runs, X-Strata recovers the full aneurysm sac, sorts crossing vessels in front or behind, and lifts both to 3D.

AgentCT: A CT Agent That Picks the Right Restoration Model

Fig. 2 of arXiv:2611.11503 by Chen, Gao, Niu, Liu, Zhang and Shan (Fudan University and co-authors): abdominal CT slices with simulated low-dose noise, sparse-view streaks and metal artifacts, comparing the degraded input, the all-in-one AMIR model, the AgentCT routed specialist and the clean reference, with zoomed regions and PSNR/SSIM.

A small vision-language model reads a CT slice, names the damage and sends it to a low-dose, sparse-view or metal specialist.

DuSS-PET: Low-Dose PET Reconstruction Without Full-Dose Pairs

Fig. 7 of arXiv:2611.11265 by Lin, He, Wang, Ma and Wang (Xi'an Jiaotong University): zero-shot brain FDG PET reconstructions on a Siemens scanner at dose reduction factors 20 and 100, comparing the low-dose input, the supervised RED model and the self-supervised DuSS-PET with the full-dose reference, plus error maps.

A self-supervised model learns to clean low-dose PET from low-dose scans alone and holds up on another vendor’s scanner.

Next →